您好!感谢您使用 “乾丰”散热器,为了帮助您更好使用产品,敬请您在安装时,遵循下列程序:
◎铜铝复合散热器产品安装注意事项
1、散热器必须由专业人员按说明书进行安装及维修;
2、确定安装位置尺寸,参照配件明细表,检查配件是否完备;(附:配件明细表)
3、安装接头、堵头、放气阀应在螺纹部位均匀涂以铅油,用生胶带顺螺纹缠绕,对好扣,用扳手将散热器固定,再用扳手将丝头、堵头、放气阀拧紧,切记不可用力过度,以免损坏散热器或散热器螺纹;
4、按安装图示,用适合的钻头钻孔,使用膨胀螺栓将挂钩进行预固定,挂钩位置处墙壁应有不小于3倍散热器重量的承受强度,使用支架固定的,依据图示安装支架,调节挂具位置,固定散热器;
5、进出水管轴心线应与散热器中心一致;
6、把进水口阀门与散热器对应接口进行连接,并用扳手拧紧;
7、散热器安装完毕后使用不小于工作压力1.5倍的压力对散热器进行试压,本体及螺栓连接处不得有泄漏。(水压试压时务必把系统中的空气排净)
Client who esteems :
Hello !
Being grateful to you to employ " the male the is abundant " heat sink , and in order to assist you better to employ the produce , invites respectfully you to be living when fixing , and following the listed below order :
The composite heat sink produce of copper aluminium is fixed paying attention to the matter
1 , the heat sink have to be fixed the maintenance according to the directions book through professional personnel staff
2 , fixs to fix the place dimensions consulting and follow the light carefully forms of parts , whether the check parts are perfect ;
( attachs : The light carefully forms of parts )
3 , fixs connector , caulking and air bleeder ought to be living that the whorl place is evenly apply with the lead oil , and the use is born the gummed type to twine with the whorl , and adjust being in good health the button , and fix the heat sink admittedly in the way of the wrench , and again in the way of the wrench shall silk head , caulking and air bleeder be screwed tightly , must always remember puting forth one's strength over , so as not to injuring heat sink either heat sink whorl
4 , notifying according to the installation picture , the use is swelled , and the bolt shall be put up Gou is underway fiing admittedly beforehand the drill bit perforate that the use is fit for , and puts up the standing intensity that the Gou place part wall properly is not smaller than 3 -fold of heat sink weight , and employ that the stand is settled admittedly , and notifys the installation stand in the light of the picture , and regulates a string apparatus place , admittedly fiing the heat sink
5 , passes in and out the string on waterpipe axle centre ought to be against the heat sink heart unanimously
6 , the grip is intake , and a mouthful valve joins against the homologous interface of heat sink , and screws tightly in the way of the wrench
7 , the heat sink installation completees , and queen employs pressure that is not smaller than work 1.5 -fold of pressure to attempt to be getting near to the heat sink , and noumenon and bolt joint part must not possess the divulgence .
( the hydraulic pressure attempies be sure to put in order the air in the system merely when being getting near )